Retrofit speeds reporting, prepares plastic panelmaker for 2000

Tom McCormick -- Control Engineering, 1/1/1999

Retrofitting a control system is tricky. Doing it and maintaining a 10-fold quality lead might seem impossible, but that's what engineers at Kemlite Co. (Joliet, Ill.) recently accomplished on one of three fiberglass-reinforced plastic (frp) panel lines.

Kemlite's panels are used in truck linings and roofing, RV exteriors, and as wall and surface paneling in cleanliness-demanding environments. Kemlite ensures its panels are as nonporous as possible and 10 times easier to clean than other frp by using a production process that doesn't "commit" the final chemistry until the frp's polyester resin is poured simultaneously with its hardening compound onto the line's polyester carrier film. This quality makes Kemlite's Glasbord frp the most specified in the U.S., especially in the health care and food industries.

Millennium upgrade

To implement its Year 2000 plan for renovating its control system, communications, and human-machine interfaces (HMI), Kemlite began by exchanging its antiquated DOS-based HMI software for a Microsoft Windows environment, installing Siemens PLCs, and replacing field device hardwiring with Profibus-DP.

This meant removing old manual controls, analog sensor inputs, and 10-year-old, hardwired PLCs with obsolete proprietary remote network. These were replaced with faster, smaller, memory-intensive Siemens PLCs, which were arranged in an open-architecture "communications pyramid" with low-level field devices and administrative mainframe computers using a common PLC language. Field-level communications were moved to Profibus-DP, which allowed Kemlite to replace individual parallel hardwiring with a single twisted-pair cable. This simplified system configuration and reduced $1,000/hr downtime costs, because control cells could now be tested offline and installed during regular maintenance and shift changeovers.

One of the most important improvements was the installation of an inexpensive HMI supplement that uses Microsoft Excel, Visual Basic subroutines and DDE communication software, and also talks with the PLC via Profibus-DP. Where the previous HMI could only log data reliably at 5-to-15-min. intervals, the new computer stations capture data from Kemlite's frp line in 15-sec. intervals. This provides rapid updates of production profiles, such as exothermic temperature readings of chemical reactions, which are crucial to the frp's overall quality control.

As a result, Kemlite is saving 40% to 50% on typical project costs. Its Joliet plant runs 10-15 projects per year, and Kemlite plans to standardize on Profibus-DP and Siemens PLCs. Profibus-PA likely will be added to complement Kemlite's Profibus-DP and Profibus-FMS configurations. The new HMI system may also use ActiveX. Object-oriented programming and greater use of Profibus optical connectivity will also be explored.

For more information, visit www.controleng.com/info


Author Information
Tom McCormick, controls engineer, Kemlite Co., Joliet, Ill.

Email
Print
Reprint
Learn RSS

Talkback

We would love your feedback!

Post a comment

» VIEW ALL TALKBACK THREADS

Related Content

Related Content

 

By This Author

There are no other articles written by this author.

Sponsored Links

 

Advertisement
SPONSORED LINKS

More Content

  • Blogs
  • Discussions
  • Webcasts
  • Podcasts
  • Videos

Blogs

  • David Chappell
    Standard profits: Make2Pack and ISA88

    December 2, 2008
    Six vendors’ automation equipment integrated easily, no questions asked
    I mentioned previously that the OMAC booth at Pack Expo 2008 would demonstrate OMAC standards. At the time, I was at “Make2Pack in Europe&hel......
    More
  • Paul Grayson
    AIMing for Automated Vehicles

    December 2, 2008
    Tuesday
    SUNDAY NIGHT WORK SESSION - SNOWSTORM Scott travels 4 hours to get to the AIM workshop and then 4 hours to get home. He usually comes over on......
    More
  • View All BlogsRSS

Webcasts

Engineering-driven Ethernet
This Control Engineering Roundtable Webcast will address the engineering issues you should be aware of when exploring the adoption of Ethernet or when looking to expand its use in your facility.

Bridging gaps with wireless
Discover how you can create stronger, flexible and cost-effective wireless connections for your entire plant. Register today!

View All Webcasts

Podcasts

Along with energy savings and other benefits, adjustable-speed drives have a downside -- a tendency to generate disruptive electrical noise. This podcast describes the EMI issues presented by AFDs and ways to mitigate them.
Silence of the Drives
Along with energy savings and other benefits, adjustable-speed drives have a downside -- a tendency to generate disruptive electrical noise. This podcast describes the EMI issues presented by AFDs and ways to mitigate them. Hear It Now

View All Podcasts Subscribe Now to Podcasts and never miss an episode
Advertisements





NEWSLETTERS

Get engineering industry news, trends, and business-critical information delivered directly to your inbox!

Click on a title below to learn more.

Weekly News (Weekly)
Process Instrumentation & Sensors (Monthly)
System Integration Monthly (Monthly)
Process & Advanced Control (Monthly)
Machine Control (Monthly)
Information Control (Monthly)
Automation Control (Monthly)
Product Review (Monthly)
Simplified Safety
Fieldbus Facts
PROFInews North American Edition
About Us   |   Advertising Info   |   Site Map   |   Contact Us   |   Useful Sites   |   FREE Subscription   |   RSS
© 2008 Reed Business Information, a division of Reed Elsevier Inc. All rights reserved.
Use of this Web site is subject to its Terms of Use | Privacy Policy
Please visit these other Reed Business sites