E-Stops and Your Compliance

October 27, 2009


STOP! Are you confusing stopping categories and risk categories? Do you wire your e-stops to a standard (non Safety) PLC or controller in order to comply with the mandatory category 0 or 1 stop? And, does your identified hazard require redundant circuits with continuous self checking and automatic diagnostics? Think twice is my advice! Yes, safety standards such as NFPA 79, clause 9.2.5.4.1.3 requires that an e-stop “shall function as either Category 0 or a Category 1 stop” as determined by the risk assessment. These are stopping functions with categories as defined by NFPA 79, clause 9.2.2.

Furthermore, your required risk analysis may require mitigation of a risk or hazard identified as Cat. 3 or 4. These are categories of risk. If you’re wiring direct to a standard PLC your e-stop may only be at best achieving Cat. 2 or less so my advice is to check your risk analysis thoroughly. Then, double check your physical application, design, and the safety ratings on all components including sensors, logic, and actuators. In short, make sure the entire circuit is completely compliant to the level of hazard (Category) and the level of stopping function with it’s associated category as determined by the risk assessment.

To be compliant - don’t confuse hazard Categories with stopping functions/categories!

Posted by J.B. Titus on October 27, 2009



For more than 30 years, J.B. Titus has advised a wide range of clients on machine functional safety solutions, including Johnson + Johnson, Siemens, General Motors, Disney, Rockwell Automation, Bridgestone Firestone, and Samsung Heavy Industries. He holds a Bachelor of Business Administration degree from Oklahoma University in industrial management and an MBA from Case Western Reserve University in marketing and finance. He is a professional member of the American Society of Safety Engineers and is OSHA-certified in machine guarding. Titus is also TUV-certified as a Functional Safety Expert and serves on several American National Standards Institute, National Fire Protection Association, and National Electrical Manufacturers Association national safety and health standards committees. Reach him at jb(at)jbtitus.com and via www.jbtitus.com.