Process Elasticity: What french fries can teach us about process control - Applied Automation, June 2012, supplement to Control Engineering, Plant Engineering. CFE Media cover photo by Peter WelanderWhen I first began learning about controls, the emphasis seemed to be all about making sure the system was as accurate as possible while meeting its dynamic specifications. That is still important, but consider a unique situation that I ran into many years ago. It was in the mid 1990s and I was working on the design of a microcontroller-based product to operate a line of commercial electric and gas-fired deep fat fryers.

The manufacturer was the second largest in the country and did not make its own controllers. The problem grew from the fact that the company wanted a unit with some rather unique features that the current supplier was not willing to provide. The controllers at that time had to be tuned individually to operate with one of 17 different model fryers. This created many logistical problems in the field with interchangeability and replacement parts.

I wracked my brain for quite a while. Clearly some sort of adaptive approach was called for, and it dawned on me that in this particular application, tight temperature control while idling was not a requirement. Plus or minus a couple of degrees would not adversely affect any product’s final quality.

I decided to use a forced-limit cycle technique. I would compel the temperature to fluctuate ±2 °F while idling and in the steady state. This is not too different from the way a common household thermostat works. Almost all fryers operate from a power relay that operates either a sophisticated gas valve or a bank of three-phase electric heaters.

The algorithm I used was unusual. I later received a patent (USP 5,575,194) for it. The technique consists of closing the heat source relay for an adjustable on time when the falling temperature crosses the setpoint. The power stays on for a predetermined length of time and then turns off.

The asymmetrical oscillations are caused by the difference in heat flow rate between the heating element operating and loss of heat to the surrounding environment.It stays off unless the temperature fails to rise back above the setpoint. If this should happen, then another pulse is initiated and its duration is lengthened by a fixed amount of time. The program periodically measures the slope of the temperature curve. In this way, it can tell if the temperature is rising, falling, or if it has peaked or bottomed out.

Four flags are key to the operation of this control. One is set if the temperature is above the setpoint, another if it is below, a third if it is falling, and the fourth if it is rising. Any time one flag is set, its opposite is automatically reset since they are mutually exclusive. In addition to these four flags, the maximum (peak) and the minimum (lowest) values are also determined and saved.

The whole idea of this approach is to establish a fixed minimum to maximum temperature swing and maintain it. As the temperature is falling from its peak, the difference between the maximum and minimum temperatures for the previous cycle is calculated:

  • If the swing was less than it should be, then the pulse count is incremented.
  • If it is right on, then no change is made.
  • If it is too wide, then the pulse count is decremented.

In this way, the limit cycle band about the setpoint is maintained while the fryer is idling. Once the controlled temperature has peaked it will start to fall. The rate at which it falls is less than the rate at which it rises when the heat has been turned on. The net result of this is an asymmetrical oscillation about the nominal setpoint. Initially a provision was made in the program to gradually adjust the nominal setpoint while in operation in order to make the oscillation symmetric about the nominal setpoint. Subsequent actual operation of the control showed that this was an unnecessary complication.

It was fascinating to watch this algorithm at work. On average it took about 5 to 10 min for the control to adapt itself to any given fryer and reach an equilibrium state. What was equally interesting was the information contained in the resulting transient wave form. The negative slope of the falling temperature is a measure of the rate of heat loss to the environment, and the positive slope is a measure of the heat gain.

Fryers have some interesting needs. The use of solid shortening, while not as prevalent today as in the past, requires the use of a melt cycle during start-up. You cannot just turn the heat full on and go. The heat must be pulsed at a rate which will allow the shortening to melt gradually and turn to liquid.

When it has been determined that the melt cycle is over, either by looking at the temperature change or just on the basis of elapsed time, the heat comes full on and stays on until the oil comes up to setpoint. Many controllers will measure the saturated rate of heat rise during this phase and compare it to that measured during the previous start. In this way it’s possible to detect any deterioration in the heating apparatus. Gas valves may need adjusting if for some reason the heat content of the gas supply may have changed. Electrical heating elements can foul or be compromised in other ways. Our adaptive control shut the heat off during the start-up phase at a programmed number of degrees below the setpoint, and then measured the overshoot. If the overshoot was higher than the value for the maximum overshoot, then the cutoff point was adjusted to a lower value or vice versa.

Cooking appliances using even eight-bit microcontrollers are not working very hard. Unless there is a lot of external communication going on, there is ample time to perform other tasks such as diagnostic testing. For example, the controller described here has a feature where it looks during start-up for the oil temperature to stall at 212 °F. This is, of course, the boiling point of water. Sometimes after a fryer has been cleaned, operators forget to drain the water and add fresh shortening. Careless operators like that have been scalded by the roiling water when they start the fryer without thinking.



No comments
The Engineers' Choice Awards highlight some of the best new control, instrumentation and automation products as chosen by...
Each year, a panel of Control Engineering editors and industry expert judges select the System Integrator of the Year Award winners.
Control Engineering Leaders Under 40 identifies and gives recognition to young engineers who...
Learn more about methods used to ensure that the integration between the safety system and the process control...
Adding industrial toughness and reliability to Ethernet eGuide
Technological advances like multiple-in-multiple-out (MIMO) transmitting and receiving
Virtualization advice: 4 ways splitting servers can help manufacturing; Efficient motion controls; Fill the brain drain; Learn from the HART Plant of the Year
Two sides to process safety: Combining human and technical factors in your program; Preparing HMI graphics for migrations; Mechatronics and safety; Engineers' Choice Awards
Detecting security breaches: Forensic invenstigations depend on knowing your networks inside and out; Wireless workers; Opening robotic control; Product exclusive: Robust encoders
The Ask Control Engineering blog covers all aspects of automation, including motors, drives, sensors, motion control, machine control, and embedded systems.
Join this ongoing discussion of machine guarding topics, including solutions assessments, regulatory compliance, gap analysis...
News and comments from Control Engineering process industries editor, Peter Welander.
IMS Research, recently acquired by IHS Inc., is a leading independent supplier of market research and consultancy to the global electronics industry.
This is a blog from the trenches – written by engineers who are implementing and upgrading control systems every day across every industry.
Anthony Baker is a fictitious aggregation of experts from Callisto Integration, providing manufacturing consulting and systems integration.
Integrator Guide

Integrator Guide

Search the online Automation Integrator Guide
 

Create New Listing

Visit the System Integrators page to view past winners of Control Engineering's System Integrator of the Year Award and learn how to enter the competition. You will also find more information on system integrators and Control System Integrators Association.

Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Control Engineering case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.