Differential-pressure flowmeter well suited to steam

V-Cone flowmeter from McCrometer provides precision monitoring in enhanced oil recovery injection applications.

05/11/2011


V-Cone flowmeter from McCrometer provides precision monitoring in enhanced oil recovery injection applications.Upstream oil & gas engineers will find McCrometer’s precision V-Cone steam-injection flowmeter supports enhanced oil recovery (EOR) technologies that produce heavy oil from demanding environments, such as shallow oil sands deposits.

Featuring a specialized flow geometry and differential pressure (DP) technology, McCrometer says its self-conditioning V-Cone flowmeter provides high measurement accuracy and repeatability over a broad flow range, regardless of fluid dynamics. Accuracy is ±0.5% with repeatability of ±0.1% over a wide turndown, even with virtually no maintenance or recalibration requirements. 

Steam injection has become an increasingly popular thermal process for third stage oil production. This EOR method is used to restore pressure, reduce viscosity, and improve flow to prolong the life of an oilfield. Steam flooding is used for shallow oil reservoirs with viscous oil, and can help reach recovery rates of 50 to 80%. 

The V-Cone reduces permanent pressure loss by 75% compared to a typical traditional orifice plate. It features a rugged design with nothing to foul or break in harsh oil production environments. The contoured shape of the V-Cone’s beta edge prevents it from dulling, reducing the need for periodic inspections and plate replacement.

The company says the V-Cone design is inherently more accurate because a flow conditioning function is built into the design. The meter’s centrally located cone interacts with the steam and reshapes the velocity profile to provide a stable signal that increases measurement accuracy.

In steam flow, the pressure difference exhibited between the meter’s static line pressure and the low pressure created downstream of the cone is measured via two pressure sensing taps, with one tap placed slightly upstream of the cone and the other located in the downstream face of the cone itself.  The pressure difference is then incorporated into a derivation of the Bernoulli equation to determine the flow rate of the steam. This effect also reduces the upstream/downstream straight pipe run required by up to 70%.

www.mccrometer.com

Visit the Control Engineering Process Control channel.

Edited by Peter Welander, pwelander(at)cfemedia.com



No comments
The Engineers' Choice Awards highlight some of the best new control, instrumentation and automation products as chosen by...
Each year, a panel of Control Engineering editors and industry expert judges select the System Integrator of the Year Award winners.
Control Engineering Leaders Under 40 identifies and gives recognition to young engineers who...
Learn more about methods used to ensure that the integration between the safety system and the process control...
Adding industrial toughness and reliability to Ethernet eGuide
Technological advances like multiple-in-multiple-out (MIMO) transmitting and receiving
Virtualization advice: 4 ways splitting servers can help manufacturing; Efficient motion controls; Fill the brain drain; Learn from the HART Plant of the Year
Two sides to process safety: Combining human and technical factors in your program; Preparing HMI graphics for migrations; Mechatronics and safety; Engineers' Choice Awards
Detecting security breaches: Forensic invenstigations depend on knowing your networks inside and out; Wireless workers; Opening robotic control; Product exclusive: Robust encoders
The Ask Control Engineering blog covers all aspects of automation, including motors, drives, sensors, motion control, machine control, and embedded systems.
Join this ongoing discussion of machine guarding topics, including solutions assessments, regulatory compliance, gap analysis...
News and comments from Control Engineering process industries editor, Peter Welander.
IMS Research, recently acquired by IHS Inc., is a leading independent supplier of market research and consultancy to the global electronics industry.
This is a blog from the trenches – written by engineers who are implementing and upgrading control systems every day across every industry.
Anthony Baker is a fictitious aggregation of experts from Callisto Integration, providing manufacturing consulting and systems integration.
Integrator Guide

Integrator Guide

Search the online Automation Integrator Guide
 

Create New Listing

Visit the System Integrators page to view past winners of Control Engineering's System Integrator of the Year Award and learn how to enter the competition. You will also find more information on system integrators and Control System Integrators Association.

Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Control Engineering case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.