IO expansion for wireless data radios

Freewave's IO Expansion modules have access times up to 192 IO points and have non-isolated inputs to reduce the number of external components.

09/02/2011


FreeWave Technologies announced a new suite of IO Expansion products to help customers achieve optimal performance, faster ROI and customization for communication networks. FreeWave’s IO Expansion modules increase the degree of monitoring, control and optimization, and offer flexible and expandable wired and wireless IO.

The new IO Expansion modules provide access times up to 192 IO points. They also offer internal user selectable pull up and pull down resistors for all non-isolated inputs to ease product installation and reduce the number of external components. Additionally, the IO Expansion products carry the same measurement accuracy of analog inputs, and can snap directly onto FreeWave radios or connect to any other serial communication device, thereby leveraging customers’ existing hardware investments.

The flexibility of IO Expansion allows it to be used for a variety of applications. In oil and gas, it is used for multiple well pad applications to obtain additional data points from the wellhead, storage tanks, separator, pipeline injection, drive and flare. In electric power, a higher concentration of IO points in a single connection simplifies transformer monitoring and eases environmental and condition monitoring of coal ash ponds. The water/wastewater market also benefits from IO Expansion with the ability to monitor and control more variables in water towers, storage ponds, pumps, drives, lift stations and chemical pumps.

New models and additional enhancements to FreeWave’s IO Expansion family include:

  • IOE-4440 Serial Base and IOEX-4440 Expansion Module - Four universal channels, four input-only channels, four isolated digital input channels and no isolated digital output channels
  • IOE-4422 Serial Base and IOEX-4422 Expansion Module - Four universal channels, four input-only channels, two isolated digital input channels and two isolated digital output channels
  • IOE-4404 Serial Base and IOEX-4404 Expansion Module - Four universal channels, four input-only channels, no isolated digital input channels and four isolated digital output channels

www.freewave.com 

Freewave Technologies

- Edited by Chris Vavra, Control Engineering, www.controleng.com 



No comments
The Engineers' Choice Awards highlight some of the best new control, instrumentation and automation products as chosen by...
Each year, a panel of Control Engineering editors and industry expert judges select the System Integrator of the Year Award winners.
Control Engineering Leaders Under 40 identifies and gives recognition to young engineers who...
Learn more about methods used to ensure that the integration between the safety system and the process control...
Adding industrial toughness and reliability to Ethernet eGuide
Technological advances like multiple-in-multiple-out (MIMO) transmitting and receiving
Virtualization advice: 4 ways splitting servers can help manufacturing; Efficient motion controls; Fill the brain drain; Learn from the HART Plant of the Year
Two sides to process safety: Combining human and technical factors in your program; Preparing HMI graphics for migrations; Mechatronics and safety; Engineers' Choice Awards
Detecting security breaches: Forensic invenstigations depend on knowing your networks inside and out; Wireless workers; Opening robotic control; Product exclusive: Robust encoders
The Ask Control Engineering blog covers all aspects of automation, including motors, drives, sensors, motion control, machine control, and embedded systems.
Join this ongoing discussion of machine guarding topics, including solutions assessments, regulatory compliance, gap analysis...
News and comments from Control Engineering process industries editor, Peter Welander.
IMS Research, recently acquired by IHS Inc., is a leading independent supplier of market research and consultancy to the global electronics industry.
This is a blog from the trenches – written by engineers who are implementing and upgrading control systems every day across every industry.
Anthony Baker is a fictitious aggregation of experts from Callisto Integration, providing manufacturing consulting and systems integration.
Integrator Guide

Integrator Guide

Search the online Automation Integrator Guide
 

Create New Listing

Visit the System Integrators page to view past winners of Control Engineering's System Integrator of the Year Award and learn how to enter the competition. You will also find more information on system integrators and Control System Integrators Association.

Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Control Engineering case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.