SEARCH Archives
Loading
Sponsored by:

Pressure transmitter for high temperature applications

Cooling neck extensions protect electronic components from hot process fluids.

07/27/2010


Baumer ED701 pressure sensorNew pressure sensor family from Baumer uses cooling neck extensions to provide heat dissipation and protect electronic components. The ED701 products can operate with high media temperatures of up to 300 °C (575 °F). Baumer says this protects the device when used in processes that require sterilization, including pharmaceutical, chemical, and food & beverage industries as well as medical technology. With that in mind, it is available with several sanitary and industrial process connections.

-----------------------------------------------------------------------------

 

40 Under 40 – Control Engineering: Know someone working in automation under age 40 in need of some recognition? See the 40 Under 40 awards.

-----------------------------------------------------------------------------

Multiple configurations are available depending on application specifics. The basic unit, without a cooling neck, is suitable up to 150 °C. Adding the standard cooling neck extends that to 200 °C, and a longer cooling neck for up to 300 °C. With built-in active compensation for temperature drifts, the ED701 has a measuring accuracy up to 0.1% full scale. This combines with 0.1% per year long-term stability and excellent repeatability. If required, the zero point can be recalibrated using a simple mechanical adjustment.

Baumer offers a range of process connections and several output signal options, including 4-20 mA, 0-10 Vdc, and 0-5 Vdc. Standard construction is stainless steel, but for use with aggressive media it can be provided with a pressure connection in Hastelloy C. For hazardous area applications, several ATEX versions are available.

Edited by Peter Welander, pwelander(at)cfemedia.com 
Control Engineering

Visit the Control Engineering Process Control Channel.



No comments

Poll of the Week

How integrated are your maintenance, controls, and instrumentation systems?
Fully integrated
Somewhat integrated
Loosely integrated
They're not


Click Here for Poll Archives
Sponsored by:

CFEMedia.com | Subscribe to Magazine | Advertise | Contact Us | About Us | Site Map | Privacy Policy
Channels | New Products | Media Library | Connect | Industry News | Events and Awards | Newsletters | Blogs | Magazine
Control Engineering | Plant Engineering | Consulting-Specifying Engineer
All content copyright © 2010-2013 CFE Media. All rights reserved.