200 Eye Street SE Renovation

Adaptive Reuse; 200 Eye Street SE Renovation; GHT Limited

08/15/2013


200 Eye Street SE Renovation. Washington, D.C. Courtesy: GHT LimitedEngineering firm: GHT Limited
2013 MEP Giants rank:
57
Project:
200 Eye Street SE Renovation
Address:
Washington, D.C., United States
Building type:
Office
Project type:
Adaptive Reuse
Engineering services:
Electrical/Power, HVAC
Project timeline:
10/26/2009 to 11/30/2012
Engineering services budget:
N/A
MEP budget: $824,000

Challenges

200 Eye Street SE is the largest project in the District of Columbia (DC) to receive double LEED Platinum certification, earning the highest level of certification under the Core and Shell and Commercial Interiors rating systems. The evolution of the building from a long-vacant printing facility to sustainably designed office space for DC government agencies was the result of a very successful public-private partnership between developer StonebridgeCarras and the DC government. GHT Limited provided mechanical, electrical, and plumbing (MEP) engineering design in partnership with the architect, Hickok Cole. The adaptive reuse of the existing base building and the tenant fit-out for the DC government agencies that occupy the facility included a complete replacement of its mechanical system. All documentation for the project was produced using Revit building information modeling (BIM) software.

Solutions

The project was open plan and open ceiling with 13-ft slab-to-slab heights over much of the project. To fulfill the client’s functional and aesthetic goals, there were many intensive working sessions to coordinate various design elements—most notably architectural and structural with mechanical. Because of the technical and design challenges involved, clear and consistent communication was required to educate the client on the design intent and confirm that it would meet the client’s needs.

The project includes a high-performance central HVAC plant; bathroom fixtures and toilets that help reduce potable water consumption by 75% per year; and a Dolphin WaterCare system, a chemical-free treatment solution that reuses discharge water and will save approximately 320,000 gal of water annually. In addition, the storm water collected through the drains is piped underground to a storage facility used by the owners of an adjacent park to supply landscape irrigation and a skating rink.



No comments
The Engineers' Choice Awards highlight some of the best new control, instrumentation and automation products as chosen by...
The System Integrator Giants program lists the top 100 system integrators among companies listed in CFE Media's Global System Integrator Database.
The Engineering Leaders Under 40 program identifies and gives recognition to young engineers who...
This eGuide illustrates solutions, applications and benefits of machine vision systems.
Learn how to increase device reliability in harsh environments and decrease unplanned system downtime.
This eGuide contains a series of articles and videos that considers theoretical and practical; immediate needs and a look into the future.
Mobile HMI; PID tuning tips; Mechatronics; Intelligent project management; Cybersecurity in Russia; Engineering education; Road to IANA
Save energy with automation; Process control system upgrades; Dispelling controll myths; Time-sensitive networking; Control system integration; Road to IANA
Additive manufacturing advancements; Machine vision enhances robotics; Fieldbus evolution; Process safety; Advice from System Integrators of the Year; Road to IANA
This article collection contains several articles on the Industrial Internet of Things (IIoT) and how it is transforming manufacturing.

Find and connect with the most suitable service provider for your unique application. Start searching the Global System Integrator Database Now!

Flexible offshore fire protection; Big Data's impact on operations; Bridging the skills gap; Identifying security risks
The digital oilfield: Utilizing Big Data can yield big savings; Virtualization a real solution; Tracking SIS performance
Getting to the bottom of subsea repairs: Older pipelines need more attention, and operators need a repair strategy; OTC preview; Offshore production difficult - and crucial
click me