A new display and visualization concept from Beckhoff Automation provides for flexible connection of up to 255 Ethernet human machine interface (HMI) panels or panel PCs to one industrial PC. CP-Link 3 is based entirely on non-proprietary hardware and the IP protocol for transfer of images. Networking can be done using standard, cost-effective Ethernet cables (CAT 5), which are suitable for dra...

05/01/2009


A new display and visualization concept from Beckhoff Automation provides for flexible connection of up to 255 Ethernet human machine interface (HMI) panels or panel PCs to one industrial PC. CP-Link 3 is based entirely on non-proprietary hardware and the IP protocol for transfer of images. Networking can be done using standard, cost-effective Ethernet cables (CAT 5), which are suitable for drag chains.

When Beckhoff introduced CP-Link 1, it offered independent display elements separate from the control level. While CP-Link 1 and CP-Link 2 solutions are based on special hardware components, CP-Link 3 is a software solution based on standard technologies: 100 Mbit/s Ethernet and IP protocol. The display contents are captured by a virtual graphic adapter in the host PC and sent using Ethernet to one or more Beckhoff Ethernet panels running Microsoft Windows CE, XP Embedded, or XP. For display communication, TCP/IP or UDP/IP (multicast) can be used depending on the operating mode.

The solution creates three operating modes with regard to screen display:

  • Single desktop : A virtual graphic adapter shows the image of the host PC on a display connected via Ethernet.

  • Extended desktop : One or several virtual graphic adapters are used as extensions to the host PC desktop. In this way, Windows can be extended to as many as nine displays.

  • Multi Desktop : All connected displays show the same image (via UDP/IP on up to 255 panels).

In multi desktop mode, an input can be made to each panel at the same time. The displays can be interlocked (mouse and keyboard) to coordinate the inputs. The host PC transfers image signals, touch screen and special key functions as well as “Virtual USB” to the panels. Virtual USB emulates a USB root hub in the host PC. If a USB device is plugged into an Ethernet Panel, the virtual hub logs the device onto the operating system of the host PC and transparently transmits the ensuing communication. For the operating system, the USB device behaves as though it was directly connected to the PC. Virtual USB transfers the standards USB 1.1 and USB 2.0.

The new CP-Link 3 concept is supported by all Beckhoff Ethernet panels and panel PCs. Users need CP-Link 3 client software and Microsoft Windows CE or XP Embedded as an operating system to implement this new technology.

www.beckhoff.com





No comments
The Engineers' Choice Awards highlight some of the best new control, instrumentation and automation products as chosen by...
Each year, a panel of Control Engineering editors and industry expert judges select the System Integrator of the Year Award winners.
The Engineering Leaders Under 40 program identifies and gives recognition to young engineers who...
Learn how to increase device reliability in harsh environments and decrease unplanned system downtime.
This eGuide contains a series of articles and videos that considers theoretical and practical; immediate needs and a look into the future.
Learn how to create value with re-use; gain productivity with lean automation and connectivity, and optimize panel design and construction.
Go deep: Automation tackles offshore oil challenges; Ethernet advice; Wireless robotics; Product exclusives; Digital edition exclusives
Lost in the gray scale? How to get effective HMIs; Best practices: Integrate old and new wireless systems; Smart software, networks; Service provider certifications
Fixing PID: Part 2: Tweaking controller strategy; Machine safety networks; Salary survey and career advice; Smart I/O architecture; Product exclusives
The Ask Control Engineering blog covers all aspects of automation, including motors, drives, sensors, motion control, machine control, and embedded systems.
Look at the basics of industrial wireless technologies, wireless concepts, wireless standards, and wireless best practices with Daniel E. Capano of Diversified Technical Services Inc.
Join this ongoing discussion of machine guarding topics, including solutions assessments, regulatory compliance, gap analysis...
This is a blog from the trenches – written by engineers who are implementing and upgrading control systems every day across every industry.
IMS Research, recently acquired by IHS Inc., is a leading independent supplier of market research and consultancy to the global electronics industry.

Find and connect with the most suitable service provider for your unique application. Start searching the Global System Integrator Database Now!

Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Control Engineering case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.