E-Stops and Your Compliance

10/27/2009


STOP! Are you confusing stopping categories and risk categories? Do you wire your e-stops to a standard (non Safety) PLC or controller in order to comply with the mandatory category 0 or 1 stop? And, does your identified hazard require redundant circuits with continuous self checking and automatic diagnostics? Think twice is my advice! Yes, safety standards such as NFPA 79, clause 9.2.5.4.1.3 requires that an e-stop “shall function as either Category 0 or a Category 1 stop” as determined by the risk assessment. These are stopping functions with categories as defined by NFPA 79, clause 9.2.2.

Furthermore, your required risk analysis may require mitigation of a risk or hazard identified as Cat. 3 or 4. These are categories of risk. If you’re wiring direct to a standard PLC your e-stop may only be at best achieving Cat. 2 or less so my advice is to check your risk analysis thoroughly. Then, double check your physical application, design, and the safety ratings on all components including sensors, logic, and actuators. In short, make sure the entire circuit is completely compliant to the level of hazard (Category) and the level of stopping function with it’s associated category as determined by the risk assessment.

To be compliant - don’t confuse hazard Categories with stopping functions/categories!

Posted by J.B. Titus on October 27, 2009



No comments
The Engineers' Choice Awards highlight some of the best new control, instrumentation and automation products as chosen by...
The System Integrator Giants program lists the top 100 system integrators among companies listed in CFE Media's Global System Integrator Database.
The Engineering Leaders Under 40 program identifies and gives recognition to young engineers who...
This eGuide illustrates solutions, applications and benefits of machine vision systems.
Learn how to increase device reliability in harsh environments and decrease unplanned system downtime.
This eGuide contains a series of articles and videos that considers theoretical and practical; immediate needs and a look into the future.
Sensor-to-cloud interoperability; PID and digital control efficiency; Alarm management system design; Automotive industry advances
Make Big Data and Industrial Internet of Things work for you, 2017 Engineers' Choice Finalists, Avoid control design pitfalls, Managing IIoT processes
Engineering Leaders Under 40; System integration improving packaging operation; Process sensing; PID velocity; Cybersecurity and functional safety
This article collection contains several articles on the Industrial Internet of Things (IIoT) and how it is transforming manufacturing.

Find and connect with the most suitable service provider for your unique application. Start searching the Global System Integrator Database Now!

SCADA at the junction, Managing risk through maintenance, Moving at the speed of data
Flexible offshore fire protection; Big Data's impact on operations; Bridging the skills gap; Identifying security risks
The digital oilfield: Utilizing Big Data can yield big savings; Virtualization a real solution; Tracking SIS performance
click me