FPI Mag Flow Meter provides accurate measurement of full flow profile

The FPI Mag Electromagnetic Flow Meter by McCrometer is ideal for municipal water or effluent wastewater treatment, provides accurate measurements via additional sensing electrodes.

01/26/2011


The FPI Mag (Full Profile Insertion) Electromagnetic Flow Meter is the successor to McCrometer’s Multi-Mag Insertion Flow Meter, which is reportedly the industry’s only multi-electrode hot tap full profile insertion flowmeter delivering a continuous total flow profile similar to a full-bore mag meter. McCrometer Flow Meter

The enhanced design of the Full Profile Insertion Flow Meter allegedly features additional sensing electrodes for increased sensitivity and is now packaged in a heavy-duty 316 stainless steel sensor body for maximum structural integrity. The sensor is coated with a NSF certified 3M fusion-bonded epoxy coating for operational longevity.

The FPI Mag with hot tap installation purportedly addresses the ever increasing need for municipalities to provide uninterrupted service 24/7, but at the same time improves process control and ensures delivery accountability. The Full Profile Insertion Flow Meter from McCrometer supposedly installs without interrupting service, de-watering lines, cutting pipe or welding flanges. Installation costs are reportedly reduced by eliminating the need for heavy equipment or extensive manpower. The FPI Mag is allegedly the industry’s most economical flow metering solution for medium and large line sizes, reducing installed costs by more than 45 percent.

The FPI Mag meter’s compact insertion design fits in confined spaces with limited access and offers total accessibility. The flow meter can be removed in pipes under pressure for easy inspection, cleaning, calibrating or verification with McCrometer’s own NIST traceable Calibration Lab. It is purportedly cost-effective for retrofit applications replacing flow meters or in sites never metered before.

The FPI Mag Flow Meter’s multi-electrode sensor design compensates for variable flow profiles, including swirl, turbulence and low-flow conditions. Multiple electrodes placed across the entire sensor body continuously measure and report the average flow rate over the full diameter of pipe.

The Full Profile Insertion Flow Meter is available for line sizes from 4 to 138 inches and rivals the performance of a full bore electromagnetic flow meter. With highly stable measurement, the FPI Mag features accuracy of ±1% of reading ± 0.03 ft/sec zero stability from 0.3 to 20 ft/s velocity range. The flow sensor comes pre-calibrated from McCrometer’s NIST traceable Calibration Lab and reportedly requires no recalibration in the field.

With no moving parts and a single-piece design, the FPI Mag’s multi-electrode sensor contains nothing to wear or break, and it is allegedly generally immune to clogging by sand, grit or other debris. The FPI Mag supports liquid flow measurement requirements in municipal water and effluent wastewater treatment. Typical municipal water applications include: wells, booster stations, effluent, filter balancing and backwash, pumping stations, UV dosing and potable water distribution.

www.mccrometer.com  McCrometer



No comments
The Engineers' Choice Awards highlight some of the best new control, instrumentation and automation products as chosen by...
Each year, a panel of Control Engineering editors and industry expert judges select the System Integrator of the Year Award winners.
The Engineering Leaders Under 40 program identifies and gives recognition to young engineers who...
Learn how to increase device reliability in harsh environments and decrease unplanned system downtime.
This eGuide contains a series of articles and videos that considers theoretical and practical; immediate needs and a look into the future.
Learn how to create value with re-use; gain productivity with lean automation and connectivity, and optimize panel design and construction.
Go deep: Automation tackles offshore oil challenges; Ethernet advice; Wireless robotics; Product exclusives; Digital edition exclusives
Lost in the gray scale? How to get effective HMIs; Best practices: Integrate old and new wireless systems; Smart software, networks; Service provider certifications
Fixing PID: Part 2: Tweaking controller strategy; Machine safety networks; Salary survey and career advice; Smart I/O architecture; Product exclusives
The Ask Control Engineering blog covers all aspects of automation, including motors, drives, sensors, motion control, machine control, and embedded systems.
Look at the basics of industrial wireless technologies, wireless concepts, wireless standards, and wireless best practices with Daniel E. Capano of Diversified Technical Services Inc.
Join this ongoing discussion of machine guarding topics, including solutions assessments, regulatory compliance, gap analysis...
This is a blog from the trenches – written by engineers who are implementing and upgrading control systems every day across every industry.
IMS Research, recently acquired by IHS Inc., is a leading independent supplier of market research and consultancy to the global electronics industry.

Find and connect with the most suitable service provider for your unique application. Start searching the Global System Integrator Database Now!

Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Control Engineering case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.