Integrating safety in automation requires specialized knowledge

In a typical automation project, maximum efficiency is key. However, undertaking a safety automation project presents additional challenges. First, legal requirements must be met. Second, care must be taken to ensure and validate that the application is truly safe. For example, is safety ensured if the equipment is misused or fails? Are you ready? Do you need a risk assessment?

08/11/2010


In a typical automation project, maximum efficiency is key. However, undertaking a safety automation project presents additional challenges. First, legal requirements must be met. Second, care must be taken to ensure and validate that the application is truly safe. For example, is safety ensured if the equipment is misused or fails?

‘Muting’ a light curtain is accomplished with additional sensors. When the sensors detect a pallet, the safety light curtain is muted. This configuration is done with a safety PLC; a safe and pre-certified muting function block ensures safe suspension of the light curtain (Source: Sick).Many people—including health and safety engineers, consultants, and safety equipment suppliers—are involved in performing a risk assessment and creating a safety plan. Fewer have a role in determining, commissioning, and implementing safety technology. In fact, often it is up to the integrator alone.

During typical automation projects, PLC programmers must adapt the system to the real-world environment and makes changes “on the fly” to get the project up and running. They often use “OR” function blocks (parallel contacts in ladder logic) and active low sensors. Both are highly critical when doing safety programming.

Consider, for example, a safety application where material has to get out of a machine, but neither a person nor any material is allowed in. This arrangement can be accomplished by “muting” a light curtain using additional sensors. Muting refers to an automatic, temporary suspension of the safety device. When the sensors detect a pallet, the safety light curtain is muted.

This configuration can be done with a safety PLC. A safe and pre-certified muting function block ensures safe suspension of the light curtain (see the diagram). Assume that the muting sensor is a reflector switch where the output is “HIGH” when it sees a reflector and “LOW” when an object is in the light path. The muting function block needs to be “HIGH” on the sensor input to mute the light curtain.

An inexperienced integrator might see no problem with this situation, saying, “Let’s negate the signal by using a ‘NOT’ function block.” Although such a solution works well and appears safe, what happens if the common power supply for the two sensors breaks down? Both sensors will switch off and it will appear to the safety PLC that they both see the object. As a result, the light curtain will be suspended.

An unsafe situation can occur easily by adapting a safe concept (function block) to a real-world scenario. An integrator needs to know his/her determination methods will influence the application. In this case, use of active “HIGH” sensors in combination with additional control signals or time monitoring functions would be required.

Integrating safety technology in a practical way requires extensive knowledge, application expertise, and many years of experience. Just as you would carefully select a qualified integrator for an automation project, make sure to do the same for the safety portion of the project by keeping them separate. This approach will ensure that safety is left to the experts. Experienced safety integrators will reduce the likelihood of safety risks during all phases of a project. Making use of simple and easy-to- use tools for design, simulation, and test also will help validate the safety functions throughout the life cycle of a machine or project.

- Juergen Bukowski is safety program manager, Sick Inc., Minneapolis, MN. Edited by Jeanine Katzel, consulting editor, Control Engineering, www.controleng.com

www.sickusa.com

Also see the Control Engineering:

Machine Safety blog

Machine Control Channel

System Integration Channel



No comments
The Engineers' Choice Awards highlight some of the best new control, instrumentation and automation products as chosen by...
The System Integrator Giants program lists the top 100 system integrators among companies listed in CFE Media's Global System Integrator Database.
The Engineering Leaders Under 40 program identifies and gives recognition to young engineers who...
This eGuide illustrates solutions, applications and benefits of machine vision systems.
Learn how to increase device reliability in harsh environments and decrease unplanned system downtime.
This eGuide contains a series of articles and videos that considers theoretical and practical; immediate needs and a look into the future.
Motor specification guidelines; Understanding multivariable control; Improving a safety instrumented system; 2017 Engineers' Choice Award Winners
Selecting the best controller from several viewpoints; System integrator advice for the IIoT; TSN and real-time Ethernet; Questions to ask when selecting a VFD; Action items for an aging PLC/DCS
Robot advances in connectivity, collaboration, and programming; Advanced process control; Industrial wireless developments; Multiplatform system integration
Motion control advances and solutions can help with machine control, automated control on assembly lines, integration of robotics and automation, and machine safety.
This article collection contains several articles on the Industrial Internet of Things (IIoT) and how it is transforming manufacturing.

Find and connect with the most suitable service provider for your unique application. Start searching the Global System Integrator Database Now!

Future of oil and gas projects; Reservoir models; The importance of SCADA to oil and gas
Big Data and bigger solutions; Tablet technologies; SCADA developments
SCADA at the junction, Managing risk through maintenance, Moving at the speed of data
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Jose S. Vasquez, Jr.
Fire & Life Safety Engineer; Technip USA Inc.

(copy 5)

click me