Machine safety: Does ISO 13849-1: 2006 weight severity, frequency, and probability equally?

New quantitative requirements for designing safety-related parts of the control system (SRP/CS) have created many discussions. Even with new requirements from ISO 13849-1, this updated standard begins with the same old qualitative approach to determine the “goal” (Performance Level required- PLr) for any safety function, asking about severity, frequency, and probability.

05/20/2013


New quantitative requirements for designing safety-related parts of the control system (SRP/CS) have created many related discussions about machine safety.  Yet, even with these new requirements from ISO 13849-1, this updated standard begins with the same old qualitative approach to determine the “goal” (Performance Level required- PLr) for any safety function. The same three questions are still asked; Severity, Frequency and Probability.

 

EN954-1 came out in 1996 with an amazing way to put more teeth into determining a hazard level and related mitigation solution for any recognized hazard. In so doing we had to analyze each hazard by evaluating the related potential injury by severity, frequency, and probability according to the graph below.

Two safety standards EN954-1 in 1996 and the 2006 ISO 13849-1 help with determining hazards and potential injury by looking at severity, frequency, and probability. Courtesy: Control Engineering Machine Safety blogTen years later in 2006 ISO 13849-1 was updated and released introducing Performance Levels and the requirement to develop the PLr, which I call the goal. To develop the PLr, we again use the qualitative approach by evaluating the related potential injury by severity, frequency, and probability also shown in the graph. There’s a whole lot more we could get into here but let’s keep it focused at the three questions.

What was the criteria for approaching these three questions in their order of severity, frequency and probability? Is severity weighted the most because it’s the first question? Such as; S = 50%, F = 30% and P = 20%? Or is probability asked last because of its greater impact? Such as; S = 25%, F = 35% and P = 40%? Or, does it matter at all? Can all three questions be equally interchanged?

J.B. Titus, CFSE

Can anybody provide some insight and background? Has this presented you with any new perspectives? Add your comments or thoughts to the discussion by submitting your ideas, experiences, and challenges in the comments section below.

 

Related articles:

Machine safety: Confusion amuck, quantitative circuit design versus qualitative risk assessment.

Machine Safety: Can end user companies comply with ISO 13849-1: 2006 without design engineering resources?

Machine Safety – incorporating “Functional Safety” as part of your machine safety plan – Part 1

 

Contact: http://www.jbtitus.com for “Solutions for Machine Safety”.



Anonymous , 05/20/13 12:41 PM:

The way I see it the starting point in the 13849-1 diagram is 50%. We go up or down from there. If you treat the severity as 25% and the two other decisions as 12.5% each, you end up with the five levels representing 0, 25%, 50%, 75% and 100%. Assuming that's what was intended, the F and P decisions can be treated as interchangeable, but S comes first. I don't know much about the rationale behind the decision process. The standard doesn't do a good job of explaining how the decision process relates to the risk reduction it shows in Figure 2.
The Engineers' Choice Awards highlight some of the best new control, instrumentation and automation products as chosen by...
Each year, a panel of Control Engineering editors and industry expert judges select the System Integrator of the Year Award winners.
Control Engineering Leaders Under 40 identifies and gives recognition to young engineers who...
Learn more about methods used to ensure that the integration between the safety system and the process control...
Adding industrial toughness and reliability to Ethernet eGuide
Technological advances like multiple-in-multiple-out (MIMO) transmitting and receiving
Virtualization advice: 4 ways splitting servers can help manufacturing; Efficient motion controls; Fill the brain drain; Learn from the HART Plant of the Year
Two sides to process safety: Combining human and technical factors in your program; Preparing HMI graphics for migrations; Mechatronics and safety; Engineers' Choice Awards
Detecting security breaches: Forensic invenstigations depend on knowing your networks inside and out; Wireless workers; Opening robotic control; Product exclusive: Robust encoders
The Ask Control Engineering blog covers all aspects of automation, including motors, drives, sensors, motion control, machine control, and embedded systems.
Join this ongoing discussion of machine guarding topics, including solutions assessments, regulatory compliance, gap analysis...
News and comments from Control Engineering process industries editor, Peter Welander.
IMS Research, recently acquired by IHS Inc., is a leading independent supplier of market research and consultancy to the global electronics industry.
This is a blog from the trenches – written by engineers who are implementing and upgrading control systems every day across every industry.
Anthony Baker is a fictitious aggregation of experts from Callisto Integration, providing manufacturing consulting and systems integration.
Integrator Guide

Integrator Guide

Search the online Automation Integrator Guide
 

Create New Listing

Visit the System Integrators page to view past winners of Control Engineering's System Integrator of the Year Award and learn how to enter the competition. You will also find more information on system integrators and Control System Integrators Association.

Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Control Engineering case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.