  • Jeff Abramson, Director of thermography development, Fluke Corp., Everett, Wash.
  • Jessica Frackleton, Senior manager of product marketing, Onset Computer Corp., Bourne, Mass.

 

CSE: What engineering challenges do you help commissioning agents (CxAs) overcome?

Fluke: Test and measurement tools help commissioning agents collect accurate data that confirms a building’s performance meets the standards and specifications it was designed against. For ventilation commissioning, many agents use airflow meters, either a multipurpose air meter that incorporates outsides air, CO, and CO2, or a single-function micromanometer. At the register and for sensor checks, most CxAs use a humidity and temperature meter and some use a handheld infrared (IR) thermometer. For building controls system signal continuity verification, sometimes a CxA will use a mA or Volts dc loop tester. When inspecting the mechanical and electro-mechanical setup, a CxA will use electrical test tools to verify supply voltage and will use thermal imagers to verify appropriate performance under load. Thermal imagers are also used for building diagnostics to inspect the overall building envelope. When assessing the lighting system, a CxA will use a light meter to measure the lumens output compared to the lighting requirements for the task or activity anticipated for that area of the building. 

Onset: For many of our customers, access to data from building automation systems (BAS) is either difficult to obtain, not sufficient, or non-existent. Our data loggers are a low-cost, minimally intrusive way of augmenting this data to pinpoint energy savings opportunities in both new and existing building commissioning. The access to this data allows for CxAs to really engineer solutions tailored to the usage and operational characteristics of each building they enter, thereby providing building owners and operators with true, measurable savings. 

CSE: What unique challenges might engineers encounter regarding the building envelope, and how would you help overcome them?

Onset: One of the most troublesome challenges that we hear from CxAs is their inability to access data the way they want it. This problem presents itself in two critically different ways:

  1. Access to data is restricted because of limitations or programming requirements of the automation systems that are in place already
  2. The physical location of the measurement point is challenging or impossible to access.

We have helped numerous projects overcome these challenges by providing data loggers that are flexible, easy to use, and allow for data to quickly be exported to any spreadsheet program or streamed seamlessly to the Web for access anywhere. We’ve worked on many projects with our clients who desire to use a combination of loggers from our standalone to our wireless data logging networks. We often hear from customers who have a lot of success with our Web-based data logging platform because it serves as an easy-to-use, flexible data logger for collecting indoor building energy information as well as localized weather data to help normalize expected energy usage throughout the year. In many commissioning projects, the flexibility to measure what you need where you need it, and manipulate the data easily can mean the difference between a successful project that quickly pays for itself a long-running headache that never yields the returns you expect.

Fluke: Air leakage is an especially tricky problem to diagnose. Using thermal imaging can show conductive heat loss due to various problems such as missing or damaged insulation. An improperly installed or configured HVAC system could take months to diagnose based on complaints from occupants, but a properly done thermal scan on the HVAC ducting could find the root cause within a day. An active HVAC system can change the thermal patterns, so it is imperative to inspect while the system is running.


<< First < Previous 1 2 3 Next > Last >>

No comments
The Engineers' Choice Awards highlight some of the best new control, instrumentation and automation products as chosen by...
The System Integrator Giants program lists the top 100 system integrators among companies listed in CFE Media's Global System Integrator Database.
Each year, a panel of Control Engineering and Plant Engineering editors and industry expert judges select the System Integrator of the Year Award winners in three categories.
This eGuide illustrates solutions, applications and benefits of machine vision systems.
Learn how to increase device reliability in harsh environments and decrease unplanned system downtime.
This eGuide contains a series of articles and videos that considers theoretical and practical; immediate needs and a look into the future.
Controller programming; Safety networks; Enclosure design; Power quality; Safety integrity levels; Increasing process efficiency
Additive manufacturing benefits; HMI and sensor tips; System integrator advice; Innovations from the industry
Robotic safety, collaboration, standards; DCS migration tips; IT/OT convergence; 2017 Control Engineering Salary and Career Survey
Featured articles highlight technologies that enable the Industrial Internet of Things, IIoT-related products and strategies to get data more easily to the user.
This article collection contains several articles on how automation and controls are helping human-machine interface (HMI) hardware and software advance.
This digital report will explore several aspects of how IIoT will transform manufacturing in the coming years.

Find and connect with the most suitable service provider for your unique application. Start searching the Global System Integrator Database Now!

Infrastructure for natural gas expansion; Artificial lift methods; Disruptive technology and fugitive gas emissions
Mobility as the means to offshore innovation; Preventing another Deepwater Horizon; ROVs as subsea robots; SCADA and the radio spectrum
Future of oil and gas projects; Reservoir models; The importance of SCADA to oil and gas
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Jose S. Vasquez, Jr.
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me