New guided wave radar level sensor options

Emerson offers new configurations for Rosemount GWR sensors to solve more complex applications.

01/19/2010


Rosemount

GWR offers new configuration options

Emerson Process Management is now offering enhancements to the single probe offering of the Rosemount 5300 Series guided wave radar (GWR), extending its use into even more applications. The new options include a thicker rod for longer measurement lengths and a Hastelloy C-276 probe and wetted parts for applications in corrosive, hot, and high pressure environments.

Emerson says the Rosemount 5300 Series features patented Direct Switch Technology (DST) which makes it possible to use a single-lead probe in more challenging applications. Combining the single-lead probe with DST provides an accurate, reliable level measurement with low-dielectric media and long measuring ranges, even for viscous media. A single-lead probe can offer benefits in some applications over the coaxial or twin lead probe since the design is not susceptible to coating problems when used with viscous media.

The new, thicker 13 mm probe is designed for an extended measurement range and is available in stainless steel for standard operating temperatures and pressures. The new Hastelloy C-276 probe and wetted parts option make the transmitter ideal for use in corrosive, hot, and high pressure environments. This enables the transmitter to be applied to oil and gas applications, including those where NACE (sulphide stress corrosion) materials are a requirement. C-276 alloy is also suitable for seawater duty and other fluids with a high chloride content. Application examples in the chemical industry include solutions containing caustic and sulphuric acid.

Emerson has expanded its range to include co-axial, twin lead, single lead, and flexible type probes to cover a wide range of applications. Rosemount's engineers expect that these new designs will be welcome in difficult installations with low dielectrics and long measuring ranges, and where the media is highly viscous, thick or dirty, where the single lead probe would normally be the preferred choice over coaxial and twin probes. This is because the coaxial and twin probe can be susceptible to product build between the inner and outer leads of the probe. Heavy coating or contamination can reduce the measuring range and may cause erroneous level readings, as well as increase the need for maintenance.

The company characterizes its Direct Switch Technology (DST) as providing a signal to the transmitter which is two- to five-times stronger than traditional GWR solutions. This gives a better signal-to-noise ratio, improved operation in low dielectric media, including over longer measuring ranges, and a better margin to handle disturbing factors. These include objects close to the probe, coating, foam, vapor, or turbulence. This means that the single lead probe design can manage most applications including interface applications.


-Edited by Peter Welander, process industries editor, PWelander@cfemedia.com
Control Engineering Process Instrumentation & Sensors Monthly eNewsletter
Register here to select your choice of free eNewsletters .





No comments
The Engineers' Choice Awards highlight some of the best new control, instrumentation and automation products as chosen by...
The System Integrator Giants program lists the top 100 system integrators among companies listed in CFE Media's Global System Integrator Database.
Each year, a panel of Control Engineering and Plant Engineering editors and industry expert judges select the System Integrator of the Year Award winners in three categories.
This eGuide illustrates solutions, applications and benefits of machine vision systems.
Learn how to increase device reliability in harsh environments and decrease unplanned system downtime.
This eGuide contains a series of articles and videos that considers theoretical and practical; immediate needs and a look into the future.
Controller programming; Safety networks; Enclosure design; Power quality; Safety integrity levels; Increasing process efficiency
Additive manufacturing benefits; HMI and sensor tips; System integrator advice; Innovations from the industry
Robotic safety, collaboration, standards; DCS migration tips; IT/OT convergence; 2017 Control Engineering Salary and Career Survey
Featured articles highlight technologies that enable the Industrial Internet of Things, IIoT-related products and strategies to get data more easily to the user.
This article collection contains several articles on how automation and controls are helping human-machine interface (HMI) hardware and software advance.
This digital report will explore several aspects of how IIoT will transform manufacturing in the coming years.

Find and connect with the most suitable service provider for your unique application. Start searching the Global System Integrator Database Now!

Infrastructure for natural gas expansion; Artificial lift methods; Disruptive technology and fugitive gas emissions
Mobility as the means to offshore innovation; Preventing another Deepwater Horizon; ROVs as subsea robots; SCADA and the radio spectrum
Future of oil and gas projects; Reservoir models; The importance of SCADA to oil and gas
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Jose S. Vasquez, Jr.
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me