Endress+Hauser's Cerabar PMP11, 21 and 23 pressure transducers measure up to 6,000 psi and are factory spanable to specific application requirements and can be used in harsh washdown environments.

By Endress+Hauser October 22, 2016

Endress+Hauser’s Cerabar PMP11, 21 and 23 pressure transducers measure up to 6,000 psi and are factory spanable to specific application requirements. The transducers are available with threaded or welded hygienic process connections and provide 4-20 mA or 0-10 Vdc output signals. The Cerabar PMP11 and PMP21 pressure transducers measure pressures from -15 to 6,000 psi at temperatures from -40 to 212°F with accuracy of 0.5% and 0.3%, respectively. The Cerabar PMP23 pressure transducers measure pressures from -15 to 600 psi at temperatures from 14 to 212°F with accuracy of 0.3%.

The IP69 housing and process isolating diaphragm are 316L stainless steel. Fully welded hygienic process connections without additional adapters or O-rings are available for washdown applications. The PMP23 can be used in CIP and SIP applications at temperatures up to 275°F for up to one hour. Transducer models with a valve plug can be fitted with the PHX20 local display. The one-line LCD shows measured values, fault messages and information messages. The device display can be turned in 90-deg steps, making it easy to reorient as required for improved readability. 

Endress+Hauser

Flow, level, liquid analysis, optical analysis, pressure, temperature measurement, software and system products | Endress+Hauser 

– Edited by CFE Media. See more Control Engineering process sensor and actuator products.