Relay: Differential current relay improves worker safety

Littelfuse RCD300M2 differential current relay improves worker safety and protects equipment from electrical ground faults. If fault current exceeds the relay trip setting, it activates and sends a signal to disconnect high potential from the equipment. Here's how it avoids an arc flash. Links are provided to other power protection products.

12/31/2008



Littelfuse RCD300M2 differential current relay improves worker safety and protects equipment from electrical ground faults.

Des Plaines, IL – The Littelfuse RCD300M2 differential current relay improves worker safety and protects equipment from electrical ground faults. Unintended conductive paths from a high potential line to ground, allow electrical currents to pass through sensitive equipment components or through personnel who touch equipment housing with devastating results. About 90% of ground faults occur slowly due to dust buildup, moisture ingress, vibration, cable chaffing, or chemical and corrosive vapors, which lead to earth-leakage or residual-current ground faults that escalate to high-current levels. Annually, appoximately 150 fires and explosions in commercial and industrial buildings are caused by electrical grounding failures, with an average loss of more than $575,000 per event (per FM Global). The worst are dangerous arc-flash events.
To avoid nuisance tripping with conventional ground fault relays, maintenance workers tend to increase trip points above sensitive levels, which defeats the purpose of having a relay sensitive enough to protect workers from electric shock or arc-flash incidents. RCD300M2 uses technology that provides highly sensitive protection, avoiding nuisance trips and unnecessary equipment shutdown.
The relay is connected to a Littelfuse WKE Series current transformer (CT), and together they sense fault current. Advanced filtering techniques differentiate between fault current and typical noise or harmonic current. If fault current exceeds the relay trip setting, it activates and sends a signal to disconnect high potential from the equipment. Seven CT sizes are available for a range of wire gages and applications. RCD300M2 can operate in a fail-safe mode by continuously checking the CT connection. If the circuit is broken, it illuminates the CT Fault lamp and activates its disconnect relay, just as if a ground fault had occurred.
Features include automated monitoring and control in power distribution panels, switchboard installations, municipal utilities, elevators, new construction sites, and similar applications, plus an adjustable time delay (0-1.5s), fault indicator LEDs, and signal output to drive a remote meter or PLC. The output gives RCD300M2 protective and predictive capabilities; leakages can be seen as they develop, and ground faults can be detected before they are critical.
Specifications include adjustable trip setting: 10 mA to 3 A; relay supply voltage: 24 V ac/dc, or 120 V ac, 50-60 Hz; two form C alarm relay contacts: 1,100 V A switching capacity (closure); 5 A continuous current; 250 V rating; breaking capacity: 3 A @ 240 V ac (P.F. = 0.4), and 0.3 A @ 110 V dc (resistive load).
Also read about:

Omron industrial relays that have easy installation with new socket options

, and

Weidmuller expanded its relays with the Riderseries family, available in kits

.
And see

Product Research on Power Protection Devices


Littelfuse

– Control Engineering News Desk
Register here and scroll down to select your choice of eNewsletters free.





No comments
The Engineers' Choice Awards highlight some of the best new control, instrumentation and automation products as chosen by...
The System Integrator Giants program lists the top 100 system integrators among companies listed in CFE Media's Global System Integrator Database.
The Engineering Leaders Under 40 program identifies and gives recognition to young engineers who...
This eGuide illustrates solutions, applications and benefits of machine vision systems.
Learn how to increase device reliability in harsh environments and decrease unplanned system downtime.
This eGuide contains a series of articles and videos that considers theoretical and practical; immediate needs and a look into the future.
Robot advances in connectivity, collaboration, and programming; Advanced process control; Industrial wireless developments; Multiplatform system integration
Sensor-to-cloud interoperability; PID and digital control efficiency; Alarm management system design; Automotive industry advances
Make Big Data and Industrial Internet of Things work for you, 2017 Engineers' Choice Finalists, Avoid control design pitfalls, Managing IIoT processes
This article collection contains several articles on the Industrial Internet of Things (IIoT) and how it is transforming manufacturing.

Find and connect with the most suitable service provider for your unique application. Start searching the Global System Integrator Database Now!

Big Data and bigger solutions; Tablet technologies; SCADA developments
SCADA at the junction, Managing risk through maintenance, Moving at the speed of data
Flexible offshore fire protection; Big Data's impact on operations; Bridging the skills gap; Identifying security risks
click me