Retrofit can stop arc flash in less than 8 ms

A new arc protection technology called GE Arc Vault, being developed by GE Consumer & Industrial's electrical distribution business for delivery in mid-2010, is said to be able to stop an arcing fault in less than eight milliseconds (ms). Furthermore, GE claims its Arc Vault system can contain an arc fault in less than eight milliseconds with the circuit breaker compartment doors open durin...

12/01/2009


 

GE says its Arc Vault System offers the fastest arc flash containment.

GE says its Arc Vault System offers the fastest arc flash containment.

A new arc protection technology called GE Arc Vault, being developed by GE Consumer & Industrial's electrical distribution business for delivery in mid-2010, is said to be able to stop an arcing fault in less than eight milliseconds (ms).

Furthermore, GE claims its Arc Vault system can contain an arc fault in less than eight milliseconds with the circuit breaker compartment doors open during operation and maintenance. The incident energy using Arc Vault, in accordance with IEEE 1584 at 24 inches from the arc event, is said to be less than 1.2 cal/cm

Traditional arc resistant switchgear provides protection as long as all circuit breaker compartment doors are closed by exhausting energy away from the area by using a chimney or plenum. Traditional arc resistant switchgear provides less protection when the circuit breaker doors are open as they are during much routine maintenance.

Optimized specifically for low voltage applications, the GE Arc Vault protection system detects an arc flash by sensing both current and light to positively indicate an arc event. When an arc flash event occurs, the system will send a signal to the arc containment device. The arc is then diverted to the containment system in less than one-half cycle or eight milliseconds. At the same time the decision to divert the arc is made, the system will also make a decision to open an upstream circuit breaker. This eliminates the fault condition and will turn off the system in approximately three cycles, at which point the fault will terminate.

The system will reduce the energy released by 63% or more compared to a bolted fault that would occur with a crowbar system, GE said. The energy reduction also lowers the stress on other system components such as transformers, circuit breakers, and equipment and improves the overall system uptime when compared to traditional arc resistant switchgear.

If an arc flash occurs during normal operation and maintenance, in many cases a contractor will be able to make the GE Arc Vault protection system operational again within a working day since fewer replacement parts are required.

A new piece of equipment containing the Arc Vault device can be located within 50 feet of the existing switchgear and the bus can be connected using cable. The detection system is run within the existing switchgear and connected to the new piece of equipment.

www.geelectrical.com/arcvault





No comments
The Engineers' Choice Awards highlight some of the best new control, instrumentation and automation products as chosen by...
The System Integrator Giants program lists the top 100 system integrators among companies listed in CFE Media's Global System Integrator Database.
The Engineering Leaders Under 40 program identifies and gives recognition to young engineers who...
This eGuide illustrates solutions, applications and benefits of machine vision systems.
Learn how to increase device reliability in harsh environments and decrease unplanned system downtime.
This eGuide contains a series of articles and videos that considers theoretical and practical; immediate needs and a look into the future.
Big Data and IIoT value; Monitoring Big Data; Robotics safety standards and programming; Learning about PID
Motor specification guidelines; Understanding multivariable control; Improving a safety instrumented system; 2017 Engineers' Choice Award Winners
Selecting the best controller from several viewpoints; System integrator advice for the IIoT; TSN and real-time Ethernet; Questions to ask when selecting a VFD; Action items for an aging PLC/DCS
This digital report will explore several aspects of how IIoT will transform manufacturing in the coming years.
Motion control advances and solutions can help with machine control, automated control on assembly lines, integration of robotics and automation, and machine safety.
This article collection contains several articles on the Industrial Internet of Things (IIoT) and how it is transforming manufacturing.

Find and connect with the most suitable service provider for your unique application. Start searching the Global System Integrator Database Now!

Future of oil and gas projects; Reservoir models; The importance of SCADA to oil and gas
Big Data and bigger solutions; Tablet technologies; SCADA developments
SCADA at the junction, Managing risk through maintenance, Moving at the speed of data
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Jose S. Vasquez, Jr.
Fire & Life Safety Engineer; Technip USA Inc.
click me