Temperature transmitter: Fieldbus networking simplifies wiring

12/20/2007



The TFZ programmable Foundation Fieldbus temperature transmitter from Moore Industries takes the analog signal from a temperature sensor and digitizes it to send the variable to the larger DCS via the H1 segment. The company says the transmitter can interface with 14 RTD types, and nine thermocouple types, as well as direct millivolt and resistance/potentiometer inputs.

The TFZ transmitter can be installed on the same segment with all standard Foundation Fieldbus devices. The bus-powered, two-wire TFZ consumes only 10.5 mA in normal operation and offers dozens of input and operation choices. It can be set up from the control room over segment wiring, using a standard Foundation Fieldbus configuration tools.

The TFZ is Factory Mutual approved for use in Class I, Division 1, Groups A, B, C, D and Class II & III, Division 1, Groups E, F, G hazardous areas. It also has NEMA 4X and IP66 ratings, approvals from ATEX, cFMus (US/Canada), IECEx, CSA, cCSAus, CENELEC/ATEX 94/9/EC and ANZEx, and is CE conformant. The TFZ operates in ambient temperature ranges of

Moore says TFZ transmitters perform continuous sensor diagnostics. This patented feature can save lost production time and simplifies troubleshooting. If the sensor breaks or otherwise stops sending a signal during operation, the transmitter instantly displays the type and location of the error on its display.

The TFZ has 20-bit input resolution, RFI/EMI protection, ambient temperature compensation, works up to five years between scheduled calibrations, and—depending on the sensor chosen—has an input accuracy up to

Resource function block (RB)—Contains diagnostic information, hardware and electronics information (memory, manufacturer identification, device type, software tag) and display configuration parameters.

Temperature transducer block (TB)—Contains temperature measurement data, including sensor and terminal temperature. It also includes information about the sensor type, engineering units, linearization, re-ranging, damping, temperature compensation and diagnostics.

Analog input block (AI)—Processes measurements from a sensor and makes them available to other function blocks. The output value from the AI block is displayed in engineering units and contains a status indicating the quality of the measurement.

—Edited by Peter Welander, process industries editor, PWelander@cfemedia.com ,
Control Engineering Weekly News





No comments
The Engineers' Choice Awards highlight some of the best new control, instrumentation and automation products as chosen by...
The System Integrator Giants program lists the top 100 system integrators among companies listed in CFE Media's Global System Integrator Database.
The Engineering Leaders Under 40 program identifies and gives recognition to young engineers who...
This eGuide illustrates solutions, applications and benefits of machine vision systems.
Learn how to increase device reliability in harsh environments and decrease unplanned system downtime.
This eGuide contains a series of articles and videos that considers theoretical and practical; immediate needs and a look into the future.
Save energy with automation; Process control system upgrades; Dispelling controll myths; Time-sensitive networking; Control system integration; Road to IANA
Additive manufacturing advancements; Machine vision enhances robotics; Fieldbus evolution; Process safety; Advice from System Integrators of the Year; Road to IANA
Salary and career survey: Benchmarks and advice; Designing controls; Remote data collection, historians; Control valve advances; Hannover Messe; Control Engineering International
This article collection contains several articles on the Industrial Internet of Things (IIoT) and how it is transforming manufacturing.

Find and connect with the most suitable service provider for your unique application. Start searching the Global System Integrator Database Now!

The digital oilfield: Utilizing Big Data can yield big savings; Virtualization a real solution; Tracking SIS performance
Getting to the bottom of subsea repairs: Older pipelines need more attention, and operators need a repair strategy; OTC preview; Offshore production difficult - and crucial
Digital oilfields: Integrated HMI/SCADA systems enable smarter data acquisition; Real-world impact of simulation; Electric actuator technology prospers in production fields
click me