Correction: IAN Head to Head on Pressure Transmitters
The Aug/Sept issue of IAN Inside Products contained incorrect information in the Head to Head chart on pressure transmitters (page 36). The Yokogawa EJX series of pressure transmitters has: The EJX in its standard configuration is also certified by TUV as complying with SIL2 for safety requirements. www.
The Aug/Sept issue of IAN Inside Products contained incorrect information in the Head to Head chart on pressure transmitters (page 36). The Yokogawa EJX series of pressure transmitters has:
A turndown ration of 200:1 in capsules M and H, and 100:1 in capsule L;
Average response time of 95 msec for capsules M and H, and 130 msec for capsule L;
A drain/vent as standard.
The EJX in its standard configuration is also certified by TUV as complying with SIL2 for safety requirements.
www.yokogawa.com