EC: I/O Expansion device
Network integration - Wireless I/O: I/O Expansion is modular I/O from FreeWave Technologies that provides universally configurable I/O and the industry's best measurement accuracy to new and existing wired and wireless process automation systems. This is a Control Engineering 2012 Engineers’ Choice finalist.
I/O Expansion from FreeWave Technologies is the newest solution for process automation, process optimization, and condition-based monitoring. Every I/O Expansion device is designed, manufactured, tested, and tuned from -40 to 75 C at FreeWave Technologies’ facilities in Boulder, Colo., to provide the most reliable remote I/O solution available. Modular expansion and universal I/O channels are at the core of I/O Expansion’s technological differentiators. The modular design makes configuration, installation, and future upgrades a snap.
The universal I/O channels allow users to train on one device and use it in any application. These Expansion modules snap directly to I/O radios or serial I/O communication modules without any additional mounting hardware or expansion backplanes. When connected to I/O radios, users can build long-range SCADA networks with distributed, expandable, wireless I/O and provide communications with distributed controllers. Alternately, users can use wireless I/O to create field networks to extend the reach of RTUs and PLCs. When connected to a serial I/O communication module, users can add expandable I/O directly to existing communications infrastructure such as licensed, unlicensed, and cellular and satellite wireless communications. Also, users can add expandable I/O to a PLC or RTU at any point in the future. Selectable EIA 232, 422, 485, or two-wire 485 interfaces support almost every device.
Universal channels provide unique differentiators to competitive I/O solutions and technologies. These channels can be configured to analog input, analog output, digital input, digital output, or sensor power. The industry’s most accurate measurement circuit takes readings from 1 V to 5 V, 0 V to 10 V, and 4 mA to 20 mA sensors without the need for external sense resistors. The maximum reading error for universal channels configured to analog input is 0.10% from -40 to 75 C. Paired with FreeWave’s diagnostics and configuration software, Tool Suite, I/O Expansion provides more data with less work.
www.freewave.com/products/allproducts/ioexpansion.aspx
FreeWave Technologies
Return to the list of the 2012 Engineers’ Choice finalists.
Do you have experience and expertise with the topics mentioned in this content? You should consider contributing to our WTWH Media editorial team and getting the recognition you and your company deserve. Click here to start this process.