Safety: controller uses Ethernet; inductive sensor positions robots
Sick IN4000 Inductive Safety Sensor is rated Category 4, in accordance with EN 954-1 (a European standard), and has an IP67 enclosure rating. Input and output signals on the sensor correspond to EN 61 131-2 and are compatible with the I/O signals on a safe PLC. |
Rockwell Automation added EtherNet/IP networking connectivity to its Allen-Bradley GuardPLC line of safety controllers, helping OEMs and end-users cost-effectively share critical safety-related information between safety and standard control systems. In a separate safety development, Sick , a manufacturer of sensors, safety systems, and automatic identification products for industrial applications, offers the IN4000 Inductive Safety Sensor, activated by metal, so it does not require a separate coded actuator. It can be connected to an IN4000 relay evaluation unit, selective Sick safety bus networks, or approved third-party safety controllers.
Four distributed I/O (DIO) modules also were recently added to the Allen-Bradley GuardPLC line of safety controllers: 8/8 digital input/output (I/O), a 16/8 digital I/O, an analog I/O, and relay output. Two digital I/O modules have bipolar outputs for use with robot controllers and other specialty output devices. Analog module has eight safety-rated inputs and four standard analog outputs. Relay module has eight isolated relays for switching power or providing a dry contact as an enable signal. GuardPLC 1600 and 1800 controllers feature a built-in, four-port Ethernet switch, making it simple to connect the I/O blocks, the company says.
Sick’s IN4000 Inductive Safety Sensor is said to be ideal for robot axis and gantry positioning to find home or safe, end-of-travel positions and to limit robot motion outside of its restricted space. It can also be used as a safeguard, for monitoring door position on a machine; the sensor can trigger a robot to stop if a door opens. The sensor is tamper-resistant and has built-in dual components and self-checking to ensure operation as a safe positioning device. It also resists shock and vibration. LEDs indicate status; self-monitoring detects failures, such as a coil break, short circuit, or cable break.
— edited by Mark T. Hoske, Control Engineering editor in chief,
MHoske@cfemedia.com
Do you have experience and expertise with the topics mentioned in this content? You should consider contributing to our CFE Media editorial team and getting the recognition you and your company deserve. Click here to start this process.