Simplified thermocouple solution provides tested, accurate results
PRODUCT FEATURES
- 1000VDC isolation per channel prevents electrical interference
- ±0.5°C accuracy (0 to 85°C) and ±1°C accuracy (-40 to 125°C)
- Built-in fault detection for open/short circuits
- IP67-rated connectors with DIN rail mounting for harsh environments
- Integration with CAN bus supported through the supplied DBC file
RELATED PRODUCTS
PRODUCT INFORMATION
MANUFACTURED BY Metis Engineering ltd
PUBLISH DATE
October 31, 2025
RELEASE DATE
September 15, 2025
MODEL/SERIES
TI8K
CATEGORY
Process Instrumentation and Sensors
Metis CAN-based, eight-channel isolated thermocouple to CAN device measures temperatures from -200°C to +1800°C at rates of up to 40 hertz per channel.
Accuracy is ±0.5/±1.5 degrees Celsius (typical/maximum) from 0 to 85 degrees and ±1/±3 degrees from -40 to 125 degrees. Each channel is isolated to 1,000 VDC. The unit includes open- and short-circuit detection to identify when a thermocouple wire is broken, disconnected or shorted to ground or power.
The unit is supplied with K-type miniature thermocouple connectors for compatibility with standard thermocouples. Other connector types — K, J, T, N, S, E, B and R — are also available.
This isolated thermocouple can be mounted on a DIN rail and includes two IP67-rated JWPF connectors for daisy-chaining with up to 128 additional modules, providing multiple measurement channels. The CAN bus speed and address are configurable and the supplied DBC file supports integration with most CAN bus systems. The input supply voltage range is 9 to 32V.
Metis Engineering
Edited by Puja Mitra, WTWH Media, for Control Engineering