Intrinsic Safety available without power limits

DART System from Pepperl+Fuchs enables process users to take full advantage of the benefits of fieldbus technology in intrinsic safety environments

04/04/2011


Pepperl+Fuchs’s Dynamic Arc Recognition and Termination System (DART) is a dynamic power supply and control system for intrinsically safe fieldbus installations that dramatically increases the power available to field devices in explosion hazardous areas, while maintaining intrinsically safe energy levels.

“The DART system supplies enough power to support nearly as many devices as is typically supplied in non-hazardous areas, and can also power field instruments that previously required more power than intrinsically safe solutions could offer,” says David Hohenstein, Department Manager, Pepperl+Fuchs. “What makes DART so unique is that it enables process users to fully benefit from the advantages of fieldbus technology in hazardous area applications such as ensuring system availability and lowering total cost of ownership.”

Early intrinsic safety solutions included the entity concept and FISCO. These enabled users to connect multiple devices to a single power supply on a fieldbus segment, but the low available power limited the number of devices per segment and reachable cable distance, forcing users to design complex bus topologies with many branches, and making fieldbus more difficult to cost-justify. More recently, the High-Power Trunk Concept (HPTC) provided users with safe installation in explosive environments, with more power supplied to the fieldbus segment while maintaining intrinsic safety at the device connection. DART represents a revolutionary next step in the evolution of intrinsic safety.

“DART is an exciting and superior option because it eliminates the power problem of intrinsic safety with a completely new approach to energy limitation. It allows for considerable higher direct power, while maintaining limitations on intrinsically safe energy via rapid disconnection,” explains Hohenstein. “Rather than taking a traditional approach to explosion prevention by limiting the available power to field devices, the DART system detects a fault condition by its characteristic rate of current change, and disconnects power before sparking can start.”

During normal operation, a DART power supply feeds full nominal power of 8 to 50 watts –more power than the approximately two watts that is normally permissible in intrinsic safety environments. Should a fault occur the potential spark remains non-incendive, and DART detects the resulting change in current and immediately switches off the power supply. In microseconds energy from the electrical system is reduced to a safe level, robbing a spark of the energy needed to ignite hazardous gases.

DART applied to fieldbus provides a higher intrinsically safe power allowance to the trunk so that the segment can support up to about 32 devices per segment – the maximum permitted per segment. This reduces capital costs by eliminating excessive fieldbus infrastructure. Moreover, cable lengths as long as 1000 meters are possible, opening up many application areas to fieldbus technology while maintaining intrinsic safety requirements for all devices and cables, including the trunk line. The higher device count per segment eliminates the problem of having to design complex network topologies with many sub-segments, each requiring its own power supply, junction boxes, and barriers.

DART technology also offers advanced diagnostics to help users rectify problems quickly and ensure system availability. And because DART Fieldbus is designed as a fieldbus infrastructure for existing IS field devices and DCS systems, or for any installation in which an intrinsically safe fieldbus segment is required, it is suitable for both green- and brown field sites.

www.pepperl-fuchs

Pepperl+Fuchs

- Edited by Gust Gianos, Plant Engineering, www.plantengineering.com



The Engineers' Choice Awards highlight some of the best new control, instrumentation and automation products as chosen by Control Engineering subscribers. Vote now (if qualified)!
The System Integrator Giants program lists the top 100 system integrators among companies listed in CFE Media's Global System Integrator Database.
Each year, a panel of Control Engineering and Plant Engineering editors and industry expert judges select the System Integrator of the Year Award winners in three categories.
This eGuide illustrates solutions, applications and benefits of machine vision systems.
Learn how to increase device reliability in harsh environments and decrease unplanned system downtime.
This eGuide contains a series of articles and videos that considers theoretical and practical; immediate needs and a look into the future.
HMI effectiveness; Distributed I/O; Engineers' Choice Award finalists; System Integrator advice; Inside Machines
Women in engineering; Engineering Leaders Under 40; PID benefits and drawbacks; Ladder logic; Cloud computing
Robotic integration and cloud connections; SCADA and cybersecurity; Motor efficiency standards; Open- and closed-loop control; Augmented reality
Programmable logic controllers (PLCs) represent the logic (decision) part of the control loop of sense, decide, and actuate. As we know, PLCs aren’t the only option for making decisions in a control loop, but they are likely why you’re here.
This digital report explains how motion control advances and solutions can help with machine control, automated control on assembly lines, integration of robotics and automation, and machine safety.
This article collection contains several articles on how advancements in vision system designs, computing power, algorithms, optics, and communications are making machine vision more cost effective than ever before.

Find and connect with the most suitable service provider for your unique application. Start searching the Global System Integrator Database Now!

Control room technology innovation; Practical approaches to corrosion protection; Pipeline regulator revises quality programs
Cloud, mobility, and remote operations; SCADA and contextual mobility; Custom UPS empowering a secure pipeline
Infrastructure for natural gas expansion; Artificial lift methods; Disruptive technology and fugitive gas emissions
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Jose S. Vasquez, Jr.
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me