Inside machines: Steelmaking application calls for consistently cool cabinets in a hot, hostile environment. Equipment specifications for data center environments are far different from those for industrial environments.

07/24/2015


Figure 1: A wallmounted enclosure is mounted on the side of an enclosure. Courtesy: RittalIndustrial enclosures used in manufacturing or process facilities need to absorb heat and protect their contents to ensure controls and automation operate safely and efficiently. Specification for data centers differs from industrial enclosure requirements. Within data centers, most of the heat generated may originate from servers inside the enclosure. In an industrial environment, more heat may be generated externally. It depends on the environment and contents of the enclosures.

Having the ability to supply enclosures and climate-control technology (fans and filters, air conditioners, heat exchangers, and process chillers) for industrial applications and data centers is especially useful when an application causes data center and industrial applications to overlap. Englewood, Colo.-based Palmer Drives Control Systems (Palmer DCS) partnered with an enclosure manufacturer to provide control panels for an application that monitors the efficiency of flames in kilns in steelmaking.

Lynn Weberg, Palmer DCS president, said that as a provider of code-compliant control panels, many of which go into hazardous locations, the company must meet specific and varied application requirements. These include a flame-monitoring panel, control panels for data collection cabinets, and modular (baying) enclosures installed in solar fields in Solano, Ariz., and Mojave, Calif. 

Keep it cool

Figure 2: A wallmounted enclosure is mounted internally onto a door of another larger enclosure. Courtesy: RittalWeberg noted that the control panels with a steel-making application were used to monitor the flame efficiency in the kilns used to obtain the fluxes important to the steelmaking process. The original equipment manufacturer (OEM) involved used a cabinet with a heat exchanger system located inside on the cabinet floor, along with an external copper-piping manifold that was expensive to build. The manifold also required a steel-cage framing system to guard against damage.

Working with the enclosure manufacturer, Palmer DCS provided the customer with pertinent data, including "operating temperatures outside the cabinets, the level of heat that the components generate during the steelmaking process, and the heat flow of the heat exchanger," according to Weberg.

The cabinet is next to a kiln that runs at 2,800 F, and the temperature outside the cabinet is 110 F; "The internal cabinet, however, must be kept much cooler," Weberg said. It uses a water-cooled heat exchanger and air conditioner, externally mounted to the side of the control cabinet, to provide adequate amounts of cool air and proper flow. The maximum cooling water temperature is 80 F.

Figure 3: Rittal was asked to partner with Englewood, Colo.-based Palmer Drives Control Systems (Palmer DCS) to provide control panels for an application that monitors the efficiency of flames in kilns in steelmaking. This Rittal TS8 Enclosure unit has aThe climate control system for the application must maintain internal operating temperatures of 41 to 86 F. Below 41 F, heating capability is required. Internal airflow baffling ensures that internal components don't exceed the specified internal operating temperatures.

Here's how the project moved from specifications to design.

Specifications to product

The enclosures used for the application are 79-in. high x 36-in. wide x 36-in. long, carbon-steel, NEMA 4/IP56-rated modular units with 19-in. rackmount rails, front and rear, separated by 24 in., front to back. Vertical rack space is 38 U. Front and rear access doors open with handles and are lockable. Doors, side panels, top and bottom panels, and externally mounted electrical enclosures are grounded.

"Once we obtained from the OEM customer the collective data points, the engineers were able to run the computations and provide the necessary analysis."

Kirk Thorne, owner of Rocky Mountain Electrical Specifications, said thermal imaging is a common tool used by data center design engineers as "Servers generate an incredible amount of heat, more than most industrial applications" with steelmaking being an exception. Still, the reality is thatk "There is far more heat in a data center than 99% of industrial applications," said Thorne.

Figure 4: The Rittal TS8 Enclosure units used for the steelmaking application are 79-in.-high x 36-in.-wide x 36-in.-long cabinets, carbon-steel, NEMA 4/IP56-rated modular units with 19-inch rackmount rails, front and rear, and separated by 24 in., frontThe equipment used to automatically process panels is 2,200 mm (about 87 in.) wide x 1,727 mm (about 68 in.) high. Equipment drills the holes on the back panel for component mounting and cuts holes in the control panel. Previously, these were manual processes.

Weberg explained, "We're generating programs that go directly to our CNC, which then cuts the holes in the back panel for the wiring and components. We know the sizes of the wires, their colors, and other information that enables us to increase efficiency and productivity by standardizing components and reusing them. This enhances collaborative efforts between our sites and our partners."

Weberg projected return on investment (ROI) for the CNC machine at 15 or 16 months.

- Mike Herzog is business manager of Rittal Automation Systems. Edited by Eric R. Eissler, editor-in-chief, Oil & Gas Engineering, eeissler@cfemedia.com.

Key concepts

  • Enclosures and climate-control technology ensure that contents of industrial applications and data centers operate reliably.
  • Some enclosure applications can require heating or cooling.
  • Industrial or data center enclosures can be modified as needed. 

Consider this

How can updated enclosure designs help your industrial control designs?

ONLINE extra - See links below.



No comments
The Engineers' Choice Awards highlight some of the best new control, instrumentation and automation products as chosen by...
The System Integrator Giants program lists the top 100 system integrators among companies listed in CFE Media's Global System Integrator Database.
The Engineering Leaders Under 40 program identifies and gives recognition to young engineers who...
This eGuide illustrates solutions, applications and benefits of machine vision systems.
Learn how to increase device reliability in harsh environments and decrease unplanned system downtime.
This eGuide contains a series of articles and videos that considers theoretical and practical; immediate needs and a look into the future.
Sensor-to-cloud interoperability; PID and digital control efficiency; Alarm management system design; Automotive industry advances
Make Big Data and Industrial Internet of Things work for you, 2017 Engineers' Choice Finalists, Avoid control design pitfalls, Managing IIoT processes
Engineering Leaders Under 40; System integration improving packaging operation; Process sensing; PID velocity; Cybersecurity and functional safety
This article collection contains several articles on the Industrial Internet of Things (IIoT) and how it is transforming manufacturing.

Find and connect with the most suitable service provider for your unique application. Start searching the Global System Integrator Database Now!

SCADA at the junction, Managing risk through maintenance, Moving at the speed of data
Flexible offshore fire protection; Big Data's impact on operations; Bridging the skills gap; Identifying security risks
The digital oilfield: Utilizing Big Data can yield big savings; Virtualization a real solution; Tracking SIS performance
click me